CellarMate 025
Unit Performance and Specs 
   
Performance    
Nominal Tonnage Ton 1/4
Nominal Compressor HP 1/3
Net Cooling Capacity*    
@ 70 DEG F Ambient BTUH 3300/3650
@ 80 DEG F Ambient BTUH 3000/3300
@ 90 DEG F Ambient BTUH 2800/3050
Controls    
Type 12-volt Thermostat    
Accuracy +/-2F  
Evaporator Section    
Fan Motor Size Watts 75
Rated Air Flow CFM 235
Air Flow with 25' flex duct CFM 207
Condenser Section    
Fan Motor Size Watts 75
Rated Air Flow CFM 253
Air Flow with 25' flex duct CFM 220
Electrical Requirements    
Power Requirements V/P/H 115/1/60
Current Draw - Cooling Mode Amps 8.6
Minimum Circuit Size Amps 15
Typical Testing Data    
Head Pressure psig 159
Suction Pressure psig 40
Condenser Inlet Temperature Deg F 81
Condenser Outlet Temperature Deg F 98
Evaporator Inlet Temperature Deg F 56
Evaporator Outlet Temperature Deg F 44
ETL Approved - Patent Pending
• The CellarMate is designed to operate at or above its rated capacities for total BTUH and CFM under recommended conditions.
  • • Net cooling capacity @ cellar temperature & humidity of 55°F & 60% RH / 60°F & 60% RH and at rated airflow.
  • • Reduce capacity by 3% for each 10% reduction in either condenser or evaporator airflow, 5% for both.
  • • All ratings @ sea level.